  • SELF-PRIMING TANK

    Installing a self-priming tank, if your SAL pump is used for vertical, upward suction, it will be possible for you to use the pump for the following applications: 1. Install where a general-purpose pump with foot valve is being used. There are many cases of problems arising with a foot valve pump because the valve…

  • FAQ-Pump Troubleshooting 5

    The pump vibrates and is noisy when operating. Below are some common causes of malfunctions and solutions.If you are unable to resolve the problem, please contact us. Cause Countermeasure The bearing is damaged  Replace the bearing Too much discharge  Adjust the discharge valve to the specified water volume. The impeller is clogged with foreign matter …

  • FAQ- Pump Trouble Shooting 4

    Overload (overcurrent) Below are some common causes of malfunctions and solutions.If you are unable to resolve the problem, please contact us. Cause Countermeasure High rotation speed. The number of poles of the motor is different.  Check the nameplate and replace it with a genuine one High voltage  Check the power supply A 50Hz pump is…

  • FAQ- Pump Trouble shooting 3

    Water comes out at first but soon stops Below are some common causes of malfunctions and solutions.If you are unable to resolve the problem, please contact us. Cause Countermeasure Insufficient priming  Prime the tank sufficiently Inhaling air  Inspect and repair the suction pipe and shaft seal. Air trapped in the suction piping  Reinstall the piping…

  • FAQ- Pump Troubleshooting 2

    The pump rotates but no water comes out. The specified discharge volume is not achieved. Below are some common causes of malfunctions and solutions.If you are unable to resolve the problem, please contact us. CAUSE Countermeasure Unprimed  To bait The gate valve is closed or ajar  Open the gate valve The rotation direction is reversed …

  • FAQ – Troubleshooting 1

    The motor does not turn. The motor hums but does not turn. Below are some common causes of malfunctions and solutions.If you are unable to resolve the problem, please contact us. Cause Countermeasure The motor is broken  Repairing an electric motor There is a problem with the power supply  Inspect and repair Rotating parts are…

  • Instruction Manual EBARA Quick Discharge connector for submersible pumps

    MODEL LS, LM, LL Safety Information and Introduction WARNING Do not work under heavy suspended object unless there is a positive support under it to stop Its fall in event of sling or hoist failure. Disregard of this war­ning could result in personal injury. This Quick Discharge Connector should only be serviced by a qualified…

  • DIAGRAMMATIC FIRE PUMP  INSTALLATIONS

    Sprinkler System        A sprinkler system is an integrated system of piping, connected to a water supply, with listed sprinklers that automatically initiate water discharge over a fire area. Usually the sprinkler system also includes a control valve and a device for activating an alarm when the system operates.          Each sprinkler has its own individual heat…

  • EBARA FSSC – INTRODUCTION

    OIL lubrication – Bearing 1,Selection of turbine oil.ISO VG46 2,Maintenance Change the oil after 300 hours for new bearings.Add oil until level is at the center of the sight glass. 3,Sight glassDimensions comply with JB/T7941.2Technical requirements comply with GB1163 Flushing for gland packing 1) If delivered liquid temperature is over than 100℃, external flushing is…

  • CLASSIFICATION OF PUMPS

    CLASSIFICATION OF TURBO PUMPS Turbo pumps are loosely grouped into the following three types.1- Centrifugal PumpPump head caused primarily by the centrifugal force of impeller rotation. This type pump is widely used for its high head capability. 2-Mixed Flow PumpHere pump head is derived partly from rotation of the impeller, partly from impeller lift. 3-Axial…

  • FUNDAMENTALS OF PUMP TECHNOLOGY

    EBARA CORPORATION I- Our lives and pump Water is essential for our lives. Although we usu­ally use water without thinking, benefits that we obtain from it are immeasurable. Life with an abundance of water is our fervent hope. Pumps help us to realize this hope and therefore we cannot do without them. It is hardly…

  • Instruction Manual EBARA Submersible Semi-Vortex Sewage Pumps DVS

    Introduction Check the following points upon receipt of your pump:(1) Is the pump exactly what you ordered? Check the name­ plate. It is especially important that you check whether the pump is to be used with 50 Hz or 60 Hz.(2) Has any damage occurred during shipment? Are any bolts or nuts loose? (3) Have…

  • Instruction Manual EBARA End Suction Volute Pumps GS

    Installation 1. Location (1) This pump should be installed indoors (except for option pump of outdoor + motor of outdoor).(2) There should be ample space around the pump, and securing a large working space for maintenance and inspection.(3) Provide an enclosure around the pump, or take some other effective measures to prevent unauthorized personnel from…

  • INSTRUCTION MANUAL EBARA HORIZONTAL SPLIT CASING CENTRIFUGAL PUMP

    Model CSA & CNA Safety Information and Introduction WARNINGBefore handling this pump, always disconnect the power first. No open flame or use spark able electrical devices or flames in a septic (gaseous) or possible septic sump. Do not work under heavy Suspended object unless there is a positive support under it to stop its fall…

  • INSTRUCTION MANUAL EBARA End Suction Volute Pump MODEL FSA

    Installation 1.LOCATION (1) This pump should be installed indoors. If it is to be used outdoors, some type of roof or covering will be required to protect the pump from the weather.(2) Install where inspection and maintenance can be easily performed.(3) Provide suitable enclosure to prevent entry of unauthorized persons.(4) Install pump as close to…

  • EBARA VERTICAL IN-LINE CENTRIFUGAL PUMP Instruction Manual

    Model LPDC 1.Installation location (1)This pump should be installed indoors. If it is to be used outdoors, some type of roof or covering will be required to protect the pump from the weather.(2) Install where inspection and maintenance can be easily performed. (3) Provide suitable enclosure to prevent entry of unauthorized persons.(4) Install pump as…

  • INSTRUCTION MANUAL EBARA Self Priming Pumps SQPB

    INSTALLATION Location(1) This pump should be installed indoors. If it is to be used outdoors, some type of roof or covering will be required to protect the pump from the weather.(2) Install in a well-ventilated area with low humidity. Ambient temperature should be 40o C or less.(3) Install where inspection and maintenance procedures can be…

  • Ebara Europe motor INSTRUCTION MANUAL REGARDING USE AND MAINTENANCE

    NEVER ALLOW THE MOTOR-DRIVEN PUMP TO OPERATE WITHOUTWATER. DOING SO CAN SERIOUSLY DAMAGE THE INTERNAL COMPONENTS. GENERAL WARNINGSa) Our surface pumps are designed to operate at a temperature no higher than40°C and a level no higher than 1000 metres;b) our motor-driven pumps cannot be used in swimming pools or similar plants; c) prolonged motor pump…

  • 03 PUMP LOAD CHART

    This chart show how 3 pump run follow time and pressure